spectra max i3x. , Fisher Scienti fi c, cat. spectra max i3x

 
, Fisher Scienti fi c, catspectra max i3x  The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes

The SpectraMax® i3x multi-mode microplate reader is a configurable, versatile microplate reader that evolves with your future needs and allows you to investigate every aspect of a cellular pathway. It allows you to explore cellular pathways and protein activation and expression in one system. SpectraMax M5. Danaher Inc spectramax i3x. HTRF IP1 standard curve measured on the SpectraMax i3x (green circles) and SpectraMax iD5 (red circles). Afterwards, 25 μL SpectraMax Glo Steady-Luc working solution was added to the wells containing luciferase and controls. The SpectraMax® i3 Multi-Mode Microplate Reader Detection Platform evolves with your future research needs and offers a breadth of application possibilities. Item SpectraMax i3x Multi-Mode Microplate Readers; Company Molecular Devices LLC; Catalog Number SpectraMax i3x <Disabled> This product is no longer available on Biocompare. 2 software (Stat-Ease) to identify factors that have significant effects on cell growth or IgG production, either alone or in combination with. Increased fluorescence performance. Immunofluorescence of In Vitro LPS-Stimulated Neutrophils. The Relative Luminescence Units (RLU) were measured using the SpectraMax i3x Luminescence Glow cartridge (Lum 384) (0200-7015POS, Molecular Devices) and normalized to the cell count or area, which were determined using the Mini MaxTM 300 Imaging Cytometer (5024062, Molecular Devices). Superior flexibility The SpectraMax i3 Multi-Mode Platform comes with standard spectral absorbance, fluorescence, and luminescence detection. Controls containing all reaction components with either DI water or a fluorescent standard in place of the fluorescent substrate were run alongside the experimental samples. The heating element design of the category 1 microplate readers, such as the SpectraMax i3x Multi-Mode Microplate Reader, applies a dual area sensor for temperature control. Plate chamber design of the SpectraMax category 1 microplate readers. 5014038F 3 Contents SafetyInformation 5 Warnings,Cautions,Notes,andTips 5 Chapter1:Introduction 11 ComputerIntegration 11 Applications 12 DualPhotomultiplierTubes 12,相关视频:多功能酶标仪SpectraMax i3x的维护操作-注射器卡盒,多功能酶标仪SpectraMax iD5的维护操作-注射器卡盒,多功能酶标仪SpectraMax i3x的维护操作-卡盒的安装和拆卸,细胞计数及活率分析仪 Vi-CELL BLU 功能&操作讲解,CRISPR基因编辑系统介绍:Cas9和Cas12a,流式. , 2014; Xiong et al. The SpectraMax® Paradigm® Multi-Mode Microplate Reader measures absorbance, fluorescence, time-resolved fluorescence (including HTRF), fluorescence polarization, AlphaScreen®, AlphaLISA®, and luminescence assays for up to 1536-well plates. The assay can accurately test the toxicology of compounds as shown in Figure 1. D 1 1. Contact our support team with your questions regarding Molecular Devices products and applications. The LDH activity in the cultural media was measured based on the reaction between LDH and lactic acid, which led to the generation of pyruvic acid, and pyruvic acid could become brown in alkaline environments with 2,4. 3, were mixed in a final volume of 100 μL in 10 mM sodium phosphate buffer, pH 7. Register to download your free eBook today. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. Structured Review. The Cuvette Chamber (SpectraMax Plus 384 only) Figure 1. The resulting absorbance was measured at 490 nm, Spectra Max i3x (Molecular Devices, USA). The information below applies to a standard 96 well plate, set to a linear shake mode. Remove the transport bracket and store the retaining screws in the bag that held the 3. KEY FEATURES • Combine cellular imaging and microplate assays into a workflow • Eliminate cell staining for cell counting and confluency with StainFree TechnologyWe would like to show you a description here but the site won’t allow us. The SpectraMax® i3 Platform from Molecular Devices® is a multi-mode detection system that evolves with your future needs and offers an unlimited breadth of application possibilities. Because a PMT needs to be set to a specified gain to reach a specific sensitivity,The SpectraMax® i3 Multi-Mode Detection Platform comes with standard spectral absorbance, fluorescence, and luminescence detection. Prepare your i3/i3x instrument for shipment. Annual recertification of your validation plates ensure that they meet specifications and give you confidence in the performance of your instrument. The SpectraMax i3x reader measures spectral-based absorbance, fluorescence, and luminescence with the added functionality of modular upgrades for western blot, imaging, and fast kinetics with injectors. Table 1. NORTH AMERICA +1 800-635-5577 Mon to Fri 7am - 5pm Pacific Time. Winnersh Triangle. Fluorescent Polarization: Solid black plates, as above. Get more information about Fluorescence Polarization SpectraMax Detection Cartridges, which offer great sensitivity for SpectraMax i3x and Paradigm Systems. For SpectraMax iD5, i3x, and Mini readers, the read height setting should be optimized for the microplate used. This is not due to a temperature-dependent alteration in cellular autofluorescence,. ) deep, preferably with access on all sides. Published Dec 16, 2020 | Updated Dec 16, 2020. Microplate Stacker. User-upgradeable detection modules allow you to expand the capabilities of your microp. Supplier: Molecular Devices. 99(图一)。The SpectraMax Injector System with SmartInject™ Technology features low dead volume (10 pL), overflow protection, and ensures. 1. 3) At the bottom of the strip, click on "Show. Easily upgrade or switch between detection modes with user-exchangeable modules – just open the drawer and insert the module you want. Page 9 Installing and Setting Up the SpectraMax MiniMax Imaging Cytometer Attaching the Imaging Cytometer to the Microplate Reader Attaching the SpectraMax MiniMax Imaging Cytometer to the SpectraMax i3x Instrument requires a work area that is approximately 130 cm (51. AlphaScreen and AlphaLisa detection using a 680 nm excitation laser diode and a 570/100 nm emission filter. Find regional support. Danaher Inc spectramax i3x Spectramax I3x, supplied by Danaher Inc, used in various techniques. SpectraMax M2, M2e; SpectraMax M3, M4, M5, M5e; FilterMax™. The SpectraMax i3x Injector Cartridge with SmartInject Technology is a data sheet that describes the features and benefits of this innovative accessory for the SpectraMax i3x Multi-Mode Detection Platform. Features. The Molecular Devices SpectraMax i3X Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence. SpectraMax i3Instrumenttovisuallyinspectyoursampleandtoruncell-basedassaysat cellularorwhole-cellresolution. The microplate was then placed in a SpectraMax i3x reader and incubated at 37°C for the duration of the kinetic measurement. The SpectraMax® i3 Platform's base system features an integrated optical system enabling top and bottom reads for 6-, 384- well microplates and launches with three broad detection modes: luminescence, absorbance, and fluorescence. Page 1 SpectraMax M3, M4, M5, and M5 ® Multi-Mode Microplate Readers User Guide 0112-0115 F July 2010. BRET2canbeusedtostudyvariouskindsofprotein-proteininteractions. • Removing the transport locks from the PMT shutters and drawers. spectramax i3x (Danaher Inc)The fluorescence emission intensity spectra were recorded using a microplate reader (Spectra Max® i3x, Molecular Devices, LLC. Native or oxidized AN (40 μM) and FN (0. The SpectraMax iD5 reader uses the HTRF detection system, which includes an Enhanced TRF Module and filters for excitation and emission. User-upgradeable detection modules allow you to expand the capabilities. This UV-visible absorbance microplate reader provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. Sensitive TRF detection of two simple, mix-and-measure assay workflows. Fluorescence Reader. **On the SpectraMax iD3/iD5 readers only All graphs are for illustrative purposes only. . D 1 1. See more, and do more, with the SpectraMax® i3/i3x Multi-Mode Detection Platform, the field-upgradeable SpectraMax® MiniMax™ 300 Imaging Cytometer enables quick imaging and analysis of cells and gives you a front-row view of phenotypic changes that accompany cytotoxicity,. Auto PMT Challenge: A standard Photomultiplier Tube (PMT) or detector limits the dynamic range of your instrument. i3x. Molecular Devices are known for both the reliability and the wide uses of their products. 6 in. Enzyme Activation Analysis;. Capture flash assays with ease The SpectraMax i3x Injector Cartridge with SmartInject® Technology expands your research capabilities to include flash-based applications including dual luciferase and ATP assays. 13. Faster data acquisition and analysis with preconfigured SoftMax Pro protocols. china@moldev. no. 2 (Molecular Devices, San Jose, CA, USA). The SpectraMax i3x microplate reader measures absorbance, luminescence and fluorescence as standard, and provides the flexibility to add novel detection capabilities without the need for service. , 1997). Auto PMT Challenge: A standard Photomultiplier Tube (PMT) or detector limits the dynamic range of your instrument. Products : FlexStation 3 reader, SpectraMax M5/M5e reader, SpectraMax M2/M2e reader. 306 plate air cal. The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes. Relative mitochondrial polarization was expressed as the ratio of emission at 590 nm to that at 530 nm (Shin et al. Be Future Ready with the SpectraMax i3x Multi-Mode Detection Platform. SpectraMax Microplate Readers. KEY FEATURES • Combine cellular imaging and microplate assays into a workflow • Eliminate cell staining for cell counting and confluency with StainFree TechnologyThe SpectraMax i3x reader measures spectral-based absorbance, fluorescence, and luminescence with the added functionality of modular upgrades for western blot, imaging, and fast kinetics with injectors. SpectraMax i3x Multi-Mode Detection Platform User Guide. Besides, it’s possible to examine each page of the guide singly by using the scroll bar. The SpectraMax i3x’s user-upgradeable application modules will future-proof your research to include most assay capabilities of the SpectraMax iD3 and iD5 readers, as well as additional capabilities such as imaging. applications, including dual luciferase and ATP assays. Table 1. SpectraMax i3x. 0112-0115G October2018 SpectraMax®M3 SpectraMax®M4 SpectraMax®M5 SpectraMax®M5e Multi-ModeMicroplateReaders UserGuideSpectraMax® Microplate Readers and SoftMax® Pro Software. 2 in. Videos & Webinars. To learn more about the device, please watch this short video. Leveraging this novel technology, researchers can: Add western blot detection to their microplate reader within 2 minutes. The SpectraMax® Paradigm® Multi-Mode Microplate Reader measures absorbance, fluorescence, time-resolved fluorescence (including HTRF), fluorescence polarization, AlphaScreen®, AlphaLISA®, and luminescence assays for up to 1536-well plates. The SpectraMax® i3x multi-mode microplate reader is a configurable, versatile microplate reader that evolves with your future needs and allows you to investigate every aspect of a cellular pathway. SPECTRAmax 340PC Microplate Spectrophotometer Operator’s Manual 1-3 Introduction General Overview The SPECTRAmax ® 340PC incorporates a holographic grating monochromator which allows you to specify a precise wavelength, from 340 nm to 850 nm, for the absorbance maximum of your sample. Get a front row view of your cells. Controls containing all reaction components with either DI water or a fluorescent standard in place of the fluorescent substrate were run alongside the experimental samples. Microplate assays were performed on a multimode microplate detector (Molecular Devices Spectra Max i3x). Avantor®, a Fortune 500 company, is a leading global provider of mission-critical products and services to customers in the biopharma, healthcare, education & government, and advanced technologies & applied materials industries. Contact Us Phone: +1. The SpectraMax® i3 Platform's base system features an integrated optical system enabling top and bottom reads for 6-, 384- well microplates and launches with three broad detection modes: luminescence, absorbance, and fluorescence. SoftMax Pro Software is an industry-leading acquisition and analysis software with over 160 ready-to-run protocols, powerful data analysis, and a range of data output options. Molecular Devices Corporation. The SpectraMax i3x reader provides theAbsorption was measured at 490 nm by utilizing a Spectra max i3x Multimode microplate reader (Molecular Devices). The SpectraMax ® i3x Platform from Molecular Devices is a multi-mode microplate reader that evolves with your future needs and offers an unlimited breadth of application possibilities. Next, an AlphaLISA assay was developed to detect levels of pro-inflammatory factors produced by endothelial cells in response to TNF-alpha stimulation. The intensity of the emitted light can be measured easily with the SpectraMax i3x reader. We would like to show you a description here but the site won’t allow us. AlphaScreen and AlphaLisa detection using a 680 nm excitation laser diode and a 570/100 nm emission filter. *On the SpectraMax i3x reader only. o For example: Ex: 485/Em 525/Cutoff 515 4. Sunnyvale, CA, USA) with excitation at 475 nm. With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user. 2 x 10-14. AquaMax Microplate Washer. In dual reporter gene assays, cells are transfected with two vectors, the first containing an experimental reporter gene coupled to a regulated promoter of interest, andSpectraMax i3x The SpectraMax i3x from Molecular Devices is a multi-mode detection system that evolves with your future needs and offers an unlimited breadth of application possibilities. Spectral Fusion Illumination is a powerful combination of Xenon flash lamp and LEDs that provides unmatched signal strength*On the SpectraMax i3x reader only. +44 118 944 8000. Besides, it’s possible to examine each page of the guide singly by using the scroll bar. 価格、見積もり、お近くの販売店を. spectramax i3x (Danaher Inc)The SpectraMax® i3x multi-mode microplate reader is a configurable, versatile microplate reader that evolves with your future needs and allows you to investigate every aspect of a cellular pathway. The SpectraMax® Mini Multi-Mode Microplate Reader offers a budget-friendly solution with three modes of detection for UV-Vis absorbance, fluorescence, and luminescence. Transfected cells were imaged on the SpectraMax MiniMax 300 Imaging Cytometer. Prepare your iD series instrument for shipment. Video: SpectraMax i3x Overview; Brochure: SpectraMax i3x Multi-Mode Detection PlatformNORTH AMERICA +1 800-635-5577 Mon to Fri 7am - 5pm Pacific Time. The SpectraMax MiniMax 300 Imaging Cytometer option can be added at any time to the SpectraMax i3x System, providing an expandable platform that evolves with your changing needs. This UV-visible absorbance microplate reader provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. Learn about the SpectraMax i3x Multi-Mode Plate Reader capabilities and options in this short video. with best-in-class data analysis software • Three modes of detection for . Absorbance Detection Cartridges combine scanning and broad spectrum wavelength range to address a variety of nucleic acids, proteins, ELISAs and immunoassays found in the laboratory. 2. ). SpectraMax® i3xMulti-ModeMicroplateReader SpectraMax® i3Multi-ModeMicroplateReader FlexStation® 3Multi-ModeMicroplateReader SpectraMax® M5eMulti-ModeMicroplateReader SpectraMax®M5Multi-ModeMicroplateReader SpectraMax® M4Multi-ModeMicroplateReader SpectraMax® M3Multi. SpectraMax i3x Multi-Mode Detection Platform. Bioz Stars score: 98/100, based on 1 PubMed citations. Pick the best speed, sensitivity, and price for your needs. It allows you to explore cellular . Bound crystal violet was dissolved with 10% acetic acid and the optical density (OD) at 570 nm was determined using a Spectra Max i3X spectrophotometer (Molecular Devices). EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. User guide for SpectraMax M5 Microplate Reader Before beginning, you should contact Tatiana Laremore (tnl1@psu. SpectraMax i3x The SpectraMax i3x from Molecular Devices is a multi-mode detection system that evolves with your future needs and offers an unlimited breadth of application possibilities. In this case, the SpectraMax i3x reader works as a flash-lamp based microplate reader as described in the supporting application note “The AutoPMT™ feature for an extended dynamic range in the SpectraMax iD and M series Multi-Mode Readers”. Cet appareil ISM est confomre à la norme NMB-001 du Canada. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. Fluorescence emission spectra were collected on an ELISA molecular system (Spectra Max i3x). ATP standard curves read on SpectraMax microplate readers. Explore a wealth of applications with the future-ready SpectraMax i3x. The chamber. User-upgradeable applications The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes. 0200-7029 Wavelength range (LUM): Visible to 650 nm Dead volume: < 10 µL with Reverse . It also integrates with the. Find regional support. 3. 4 / 5. 蛍光 発光 ELISA. Immunofluorescence StainingAfter cooled down to room temperature, the concentrations of the solution were measured by microplate reader (Spectra Max i3x) at 490 nm (Kagi and Schaffer, 1988). . . 蛍光 発光 ELISA. SpectraMax M 시리즈 Microplate Reader, Cuvette Port, IQ OQ 검증 | Molecular Devices. It features a modular design that allows users to add or change detection cartridges according to their needs. Preconfigured protocols and custom assay workflows simplify microplate data acquisition and analysis. Unpacking and setting up the instrument includes the following procedures: • Unpacking the instrument and saving the original packaging. Detection of pro-inflammatory factors. Recommendations for SpectraMax i3/i3x plate readers The Molecular Devices SpectraMax i3/i3x allows use of the pH-Xtra Glycolysis Assay with time-resolved fluorescence (TRF) detection. Description 1. Hands-on fun and learning that empowers exploring, inventing and sharing. Wokingham, Berkshire RG41 5TS United Kingdom. Examples: fiPress carefully to engage,fl fiDo not press down. Flow cytometry was used to measure ROS concentrations, based on fluorescence intensity (FL-1, 530 nm) of 10,000 cells. Other services inlcude but are not limited to anti-drug activity (ADA), PK/PD assays as well as antibody screenings. Assay setup for a 384-well low-volume plate. Learn how you can perform flash-based applications, such as dual luciferase and ATP assays, with high precision and accuracy using this cartridge. The ratio of the two fluorescence intensities 520/620 (acceptor/donor) enables the calculation of Delta F (%) which. Devices instruments including: SpectraMax®, VersaMax, VMax®, EMax®, Gemini, ThermoMax, and FlexStation® readers. The SpectraMax i3 Platform's base system features an integrated optical system enabling top and bottom reads for 6 - 384 well microplates and launches with three broad detection modes: luminescence, absorbance, and fluorescence. Simplified workflow: Add cellular imaging assays in a small footprint. ATP concentration (M) Average RLU SpectraMax L SpectraMax i3x (cartridge) SpectraMax Mini SpectraMax iD5 SpectraMax i3x (onboard) SpectraMax M5e Fluorescence was quantified using a microplate reader (SpectraMax i3x, Molecular Devices, CA, USA) with an excitation and emission wavelength being 365 nm and 450 nm, respectively (Jian et al. HTRF is a proprietary time-resolved fluoresce nce technology that overcomes This assay workflow is easily performed using the SpectraMax i3x Multi-Mode Microplate Reader with SpectraMax Injector Cartridge, which is fully DL Ready validated. The SpectraMax® i3x multi-mode microplate reader is a configurable, versatile microplate reader that evolves with your future needs and allows you to investigate every aspect of a cellular pathway. The SpectraMax i2X is used for cell migration, cell. Keywords: fluorescence polarization, spectramax detection cartridge, spectramax paradigm readers, spectramax paradigm, upgredeable cartridge, Created Date: 8/1/2013 10:01:48. Located at the right front of the SpectraMax Plus 384, the cuvette chamber has a lid that lifts up, allowing you to insert or remove a cuvette. Get a front row view of your cells. Explore a wealth of applications with the future-ready SpectraMax i3x. 4. The treatments were. **On the SpectraMax iD3/iD5 readers only All graphs are for illustrative purposes only. HTRF IP standard curve. Because a PMT needs to be set to a specified gain to reach a specific sensitivity,*On the SpectraMax i3x reader only. SpectraMax® i3x Multi-Mode Detection Platform, Molecular Devices. 10, and 0. ZERO BIAS - scores, article reviews, protocol conditions and moreWe would like to show you a description here but the site won’t allow us. With optimized reagents and the industry-leading data acquisition and analysis tool SoftMax® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. SpectraMax M2, M2e; SpectraMax M3, M4, M5, M5e; FilterMax™ Multi-Mode Detection. Bioz Stars score: 98/100, based on 1 PubMed citations. SoftMax Pro GxP Compliance Software. 001 0. The SpectraMax® 190 spectrophotometer is ideal for most life science applications, especially DNA analysis. Detection cartridge modularity allows for easy addition of new read modes within minutes without. Spectranet customer portalThe Relative Luminescence Units (RLU) were measured using the SpectraMax i3x Luminescence Glow cartridge (Lum 384) (0200-7015POS, Molecular Devices) and normalized to the cell count or area, which were determined using the Mini MaxTM 300 Imaging Cytometer (5024062, Molecular Devices). This technical note demonstrates validation of the SpectraMax® i3x Multi-Mode Microplate Reader for NanoBRET™ assays. The SpectraMax MiniMax 300 Imaging Cytometer option can be added at any time to the SpectraMax i3x System, providing an expandable platform that evolves with your changing needs. Modularity does provide some measure of forward vision into upcoming or future experimental needs. Detection of pro-inflammatory factors. Find regional support. Synthesis of ZM-1NORTH AMERICA +1 800-635-5577 Mon to Fri 7am - 5pm Pacific Time. The SoftMax Pro Software provides integrated instrument control. HTRF is a proprietary time-resolved fluoresce nce technology that overcomesThe SpectraMax i3x reader features a cooled photomultiplier tube (PMT) for low background noise in luminescence. Bookings are free, but you will need to use iLab to book. Italic and boldface type are used for emphasis. Patented user-exchangeable cartridge design expands the system's detection capability making it. Our microplate readers and software are the industry’s most cited and have empowered life science researchers to advance protein and cell biology. Additionally, user-installable options allow the SpectraMax i3 System to grow with your changing application needs to fulfill and go beyond the standard reader applications, protecting your intial investment. The Molecular Devices SpectraMax i3x is a multi-mode microplate reader, able to measure UV/vis, fluorescence and luminescence. The SpectraMax i3x reader is engineered to perform with Spectral Fusion Illumination for increased sensitivity across the entire wavelength range, and a cooled photomultiplier tube (PMT) for improved detection in extremely. com Check our website for a current listing of worldwide distributors. The chamber. The SpectraMax i3x reader provides the. Located at the right front of the SpectraMax Plus 384, the cuvette chamber has a lid that lifts up, allowing you to insert or remove a cuvette. Find regional support. The SpectraMax® i Series Multi-Mode Mode Microplate Readers offer the ideal solution for any application or budget. 0´ 104 8. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. As. See5039228D December2018 SpectraMax® i3x Multi-ModeDetectionPlatform WiththeSpectraMax® MiniMax™300ImagingCytometer UserGuideMolecular Interactions. The SpectraMax® M5 Multi-Mode Microplate Reader delivers single mode reader performance and can be equipped to read volumes as low as 2uL in one multimode reader package. Overview of SpectraMax MiniMax 300 Imaging Cytometer. eu@moldev. Explore more about the SpectraMax i3x Multi-Mode Plate Reader, a user-upgradeable detection modules allow you to expand the capabilities of your microplate reader when your research requires it. g. CHO M1WT3 cells are Chinese hamster ovary cells stably transfected with the M1 muscarinic G q -coupled receptor. Promega. Specifically, we present neurite. The SpectraMax i3x microplate reader measures absorbance, luminescence and fluorescence as standard, and provides the flexibility to add novel. The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes. The plate reader optics are tunable for absorbance, fluorescence intensity, fluorescence. Molecular Devices’ SpectraMax i3x Multi-Mode Microplate Reader and Thermo Fisher Scientific’s Varioskan LUX reader also perform multiplexing. Devices instruments including: SpectraMax®, VersaMax, VMax®, EMax®, Gemini, ThermoMax, and FlexStation® readers. 7°C and the bottom to 36. Select PMT gain o PMT gain = energy used by detector to collect signal o Low gain for samples with high expected signalSpectraMax i3x Multi-Mode Microplate Reader. Manufacturers try to design their instruments so they can be. SoftMax Pro GxP software is a special release that includ es full user and permission control and audit trail generation in addition to all the dataThe SpectraMax i3x reader and MiniMax cytometer can be used with FluoroBlok cell culture inserts to directly count cells from high-quality images to measure cellular migration over time. iD5. The fluorescence spectra was obtained on a Spectra Max i3x Multi-Mode Detection Platform. 2. Figure 1. The MPO assay was conducted according to the. The SpectraMax i3x reader provides the With these results, as well as CV values below 6% for all standards, both the SpectraMax i3x and the SpectraMax iD5 readers demonstrate high sensitivity and a wide dynamic range for the IP-One assay. VersaMax, SpectraMax 340PC384, 190, Plus 384 Microplate Readers User Guide Electromagnetic Compatibility Regulatory for Canada (ICES/NMB-001:2006) This ISM device complies with Canadian ICES-001. 99. The SpectraMax® i3 Multi-Mode Detection Platform comes with standard spectral absorbance, fluorescence, and luminescence detection. 01 0. The SpectraMax ® i3x reader provides the. The SpectraMax i3x reader allows you to unravel the mysteries of science by exploring SpectraMax i3 Install Guide; SpectraMax i3; SpectraMax i3x; SpectraMax iD3; SpectraMax iD5; SpectraMax Mini; SpectraMax Mini Install Guide; SpectraMax Mini Reader Plug-In Download Page (required for SoftMax Pro 7. Fluorescence intensity was measured using a Spectramax i3x plate reader (Molecular Devices) with excitation at 575 nm (bandwidth 9 nm) and emission at 608 nm (bandwidth 15 nm). Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire. This technical note demonstrates validation of the SpectraMax® i3x Multi-Mode Microplate Reader for NanoBRET™ assays. 1 1 10 100 e e e e e e eThe SpectraMax MiniMax 300 Imaging Cytometer option can be added at any time to the SpectraMax i3x System, providing an expandable platform that evolves with your changing needs. SPECTRAmax 340PC Microplate Spectrophotometer Operator’s Manual 1-3 Introduction General Overview The SPECTRAmax ® 340PC incorporates a holographic grating monochromator which allows you to specify a precise wavelength, from 340 nm to 850 nm, for the absorbance maximum of your sample. Description: The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research. infoboxeu@moldev. Because a PMT needs to be set to a specified gain to reach a specific sensitivity,The SpectraMax® M5 utilizes a single monochromator design for UV/VIS Absorbance, allowing the user to maximize sensitivity and tunability, and also uses patented PathCheck® Pathlength Measurement Technology:. Benefits • User-upgradeable application modules including cellular imaging • Sensitivity across spectrum with Spectral Fusion™ Illumination • Expanded dynamic range with cooled PMT • Control and analytics provided by SoftMax® Pro Software SpectraMax i3x The SpectraMax i3x from Molecular Devices is a multi-mode detection system that evolves with your future needs and offers an. SpectraMax® i3x Multi-Mode Detection Platform, Molecular Devices. With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user. SpectraDrop Abs Protein Quant (i3-i3x)Molecular Devices SpectraMax i3x Multi-Mode Detection Platform. 4. This way you’ll save time on finding the necessary info. The SpectraMax i3 also allows the user to identify antibodies during Elisa Assays. MD Neurotransmitter Transporter Assay. We would like to show you a description here but the site won’t allow us. SPECTRAmax 190 Microplate Spectrophotometer Operator™s Manual vii Conventions Used in this Manual The names of keys that appear on the SPECTRAmax 190 control panel are shown in boxed Helvetica type. The SpectraMax DuoLuc Reporter Assay has been performance optimized on the SpectraMax i3x reader with Injector Cartridge. 2. Figure 4. **On the SpectraMax iD3/iD5 readers only All graphs are for illustrative purposes only. This eBook shows how to see more and do more with an imaging cytometer that enables rapid imaging and cell analysis. the SpectraMax Paradigm Multi-Mode Detection Platform User Guide. Check software compatibility with Windows 10 and locate your software installer. The SpectraMax i3x microplate reader measures absorbance, luminescence and fluorescence as standard, and provides the flexibility to add novel. For 40 years, we have partnered with scientists to help them achieve landmark discoveries. The SpectraMax® i3x multi-mode microplate reader is a configurable, versatile microplate reader that evolves with your future needs and allows you to investigate every aspect of a cellular pathway. Increased fluorescence performance. 1) Select the correct plate and the wells that you want to measure. Replicate values were averaged and imported into Design-Expert 8. It allows the user to determine the total concentration of protein in a solution. Figure 1. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader. The Cuvette Chamber (SpectraMax Plus 384 only) Figure 1. SpectraMax i3/i3x readers must be equipped with a suitableWhen we measured the FRET ratio using the Spectramax i3x plate reader, we found that FRET ratios were higher in DMSO-treated cells that had not been incubated at room temperature to enhance fluorescence than in room temperature-incubated cells (Fig. SpectraMax® i3 Multi-ModeDetectionPlatform withtheSpectraMax® MiniMax™ImagingCytometer UserGuide 5025027A April2013. ValitaTiter Plus settingsThe SpectraMax® iD3 Multi-Mode Microplate Reader is the cornerstone of a complete laboratory solution to help you expand the boundaries of your research capabilities. 価格、見積もり、お近くの販売店を. Fluorescence was measured using a microplate fluorometer (SpectraMax i3x, Molecular Devices, Beckman Coulter, CA, USA) with 365 nm excitation and 450 nm emission filters. Because a PMT needs to be set to a specified gain to reach a specific sensitivity,SpectraMax M3 Plate Read, Plate Map, Data Analysis and Export Setup pg. SoftMax Pro GxP software is a special release that includ es full user and permission control and audit trail generation in addition to all the datathe SpectraMax i3x Multi-Mode Microplate Reader with SpectraMax Injector Cartridge Introduction Reporter gene assays are used to study the expression of eukaryotic genes. Contact Local Team. The SpectraMax ® i3x Multi-Mode microplate reader measures spectral-based Absorbance, Fluorescence, and Luminescence with the added functionality of modular. The calculated LOQ values were 0. Afterwards, 25 μL SpectraMax Glo Steady-Luc working solution was added to the wells containing luciferase and controls. In SoftMax® Pro, the following Automix settings are available for the SpectraMax i3/i3x Instrument: Intensity : Low, Medium, or High. Increased fluorescence performance. Detection cartridge modularity allows for easy addition of new read modes within minutes without. Lower limits of detection for ATP determined using the ATPlite . Because microplate readers are meant to shoulder routine and time-consuming tasks for researchers, ease of use is an important feature. com. CRITICAL STEP Avoid air bubbles; reverse pipetting the luciferase reagent into the plate is a good way to achieve this. Download PDF. Learn how the SpectraMax Paradigm Multi-Mode Detection Platform with Tunable Wavelength (TUNE) Detection Cartridge combines the flexibility of wavelength scanning with the high sensitivity of filters. The FRET ratio is defined as the relative fluorescence intensity of an acceptor normalized to the total fluorescence intensity. The ScanLater Western Blot Detection Cartridge is a user-installable option for the SpectraMax i3, i3x and Paradigm Multi-Mode Readers. **On the SpectraMax iD3/iD5 readers only All graphs are for illustrative purposes only. Prepare your i3/i3x instrument for shipment. Thetypeof luciferase(Renilla. **On the SpectraMax iD3/iD5 readers only All graphs are for illustrative purposes only. Anne T. Key features. Additionally, user-installable options allow the SpectraMax i3 System to grow with your changing application needs to fulfill and go beyond the standard reader applications, protecting your intial investment. 06, 0. Leveraging this novel technology, researchers can: Add western blot detection to their microplate reader within 2 minutes. ZERO BIAS - scores, article reviews, protocol conditions and more. The SpectraMax® Mini Multi-Mode Microplate Reader offers a budget-friendly solution with three modes of detection for UV-Vis absorbance, fluorescence, and luminescence. GFP expression imaged on the cytometer. The SpectraMax i3x reader is engineered to perform with Spectral Fusion Illumination for increased sensitivity across the entire wavelength range, and a cooled photomultiplier tube (PMT) for improved detection in extremely low light. 2 GxP Software is the latest, most secure software to achieve full FDA 21 CFR Part 11 and EudraLex Annex 11 compliance with. The TUNE detection cartridge uses a breakthrough monochromator design that enables researchers to easily optimize their. Every SpectraMax ® Paradigm Detection Cartridge starts with an application optimized excitation energy source either in the form of a long life, high powered LED, xenon flash lamp, or high powered laser. 6% for the on-board optics (monochromators). Using the SpectraMax i3x reader, the preconfigured SpectraMax Glo Steady-Luc Reporter assay protocol in SoftMax Pro Software was used to measure luminescence. 在SpectraMax i3x和SpectraMax iD5微孔板读板机上使用 SoftMax Pro软件绘制标准曲线,并进行4参数曲线拟合(图 4),结果见表2。使用EC50评估该测定方法的适用性,EC50值 应低于150 nM。对于两个读板机,EC 50值均低于85 nM,处 于可接受范围内。Cisbio将可接受的信噪比定义为≥. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a. Microplate and read height should be optimized for each new lot of microplates or assay volume used (use the Show Pre-Read Optimization options in the instrument settings in SoftMax Pro Software). Spectranet customer portalThe SpectraMax Paradigm Multi-Mode Detection Platform is a modular multi-mode microplate detector. Figure 2-23: Bottle holder To install the bottle holder: 1. 11. User-upgradeable detection modules allow you to expand the capabilities of your microplate reader when your research requires it. 0´ 104 6. flThe SpectraMax M2 and M2e systems provide the multi detection microplate readers with dualmonochromators, dual-mode cuvette ports, with top & bottom reading. Image analysis provides accurate data. SpectraMax i3x offers all the techniques you need to explore cell pathway in a single system. The SpectraMax i3x reader provides theWith these results, as well as CV values below 6% for all standards, both the SpectraMax i3x and the SpectraMax iD5 readers demonstrate high sensitivity and a wide dynamic range for the IP-One assay. 303 unable to cal dark current. The SpectraMax MiniMax 300 Imaging Cytometer option can be added at any time to the SpectraMax i3x System, providing an expandable platform that evolves with your changing needs. More Product Information. 6% for the on-board optics (monochromators).